Stairs & Balustrades
Frameless or aluminium-framed balustrades in tempered laminated glass meeting load requirements.

A glass balustrade should be laminated in most cases: a barrier that disappears when it breaks is no longer a barrier. Thickness follows the fixing system, the height and the required horizontal load, and is not picked from a generic table.
Fixing systems
| System | Consequence |
|---|---|
| Base-fixed | Thick laminated, structural calculation mandatory |
| Point-fixed | Holes before tempering, without exception |
| Top and bottom framed | Lower thickness possible |
| With handrail | Distributes load and relaxes the requirement |
The interlayer
PVB is sufficient for most uses. SGP is stiffer and holds the panel's shape after breakage, which is why it is preferred for base-fixed systems and greater heights. The difference is structural, not cosmetic.
What is fixed before fabrication
- Height from finished floor level, not from the concrete.
- Positions of holes and cut-outs.
- Edge treatment, because here the edge is both seen and touched.
The structural calculation is the project engineer's responsibility; fabrication follows the approved dimensions and specification.
Key Advantages
- Tempered laminated glass
- Meets load requirements
Technical Specifications
| Build-up | 10+10 mm laminated |
|---|
Applications
- Staircases
- Balconies
- Atriums
Production Line

Cutting, Edging & Beveling
Custom cutting sets the shape of the glass; edging refines its perimeter; beveling creates an angled decorative edge. Together they turn a glass sheet into a panel suited to a specific mirror, furniture piece, partition or door. Accurate drawings make the finish usable as well as attractive.

Glass Tempering
Tempered glass is heat-treated glass used where greater resistance and a safety breakage pattern are needed. For a Riyadh villa bathroom, shop door or office partition, the right specification includes the complete panel, its fittings and its supports—not thickness alone.
Frequently Asked Questions
How thick should balustrade glass be?
There is no single thickness; it follows the fixing system, height and horizontal load, and is set by the project's structural calculation.
Is tempered glass enough for a balustrade?
On balconies and stairs over a drop, single tempered glass is usually not enough; laminated glass is used, often from two tempered panes, because it stays in place if it breaks.
Can a shower specification be used for a stair balustrade?
Not automatically. A balustrade performs a barrier function and needs its loads, fixings and system safety reviewed.
Related Guides

Low-Iron Glass: When Is It Worth It, and Why Does Ordinary Glass Look Green at the Edge?
Low-iron glass is worth its cost where the edge, thickness or what sits behind the glass is seen: balustrades and showers with exposed edges, display fronts, glass over white surfaces and light back-painted glass. In framed windows and tinted glass the difference is barely visible.
29 November 2026 · 5 min read

Glass Balustrade Guide: Tempered or Laminated, Fixing Systems and Thickness
A glass balustrade is laminated in most cases, often from two tempered panes, because it stays in place if it breaks. Thickness follows the fixing system, height and horizontal load and is calculated by the project engineer; the final measurement is taken after floor finishes.
5 September 2026 · 5 min read

How Do You Choose Glass Thickness for a Riyadh Project?
Choose glass thickness from panel dimensions, supports, loads and intended use, not area alone. Prepare your project information before approving fabrication.
10 August 2026 · 5 min read

Tempered or Laminated? A Selection Guide
Both are safety glass but they solve different problems. The question is not which is stronger but what happens when the pane breaks: tempered falls, laminated stays in place.
1 August 2026 · 6 min read
Request a Quote