Insulated glass units: how they work and what to specify
September 5, 2026 · 6 min read
An insulated glass unit is not just two panes. The spacer, the desiccant and the seal decide how long it actually lasts.

AI-generated illustration, not a photograph of a completed project.
An insulated glass unit (IGU) is two or more panes separated by a sealed cavity filled with dry air or argon. The performance comes from the cavity and the coating, not from the thickness of the glass. Thicker panes add weight faster than they add thermal performance.
What the unit is made of
| Component | Function | Effect of the choice |
|---|---|---|
| Outer pane | Faces sun and dust | Usually carries the coating |
| Cavity | Reduces heat transfer | 12-16 mm is the practical range |
| Spacer | Sets the cavity width | A warm-edge spacer reduces edge condensation |
| Desiccant | Absorbs moisture in the cavity | Prevents internal fogging |
| Dual seal | Retains gas, blocks vapour | The main factor in unit lifespan |
Where the coating goes
Surfaces are numbered from outside in. In a hot climate a low-E coating goes on surface 2, the inner face of the outer pane, because the aim is to reject radiation before it enters. In a cold climate the logic differs. Naming the surface number in the specification prevents an expensive misunderstanding.
Why units fail
- A weak seal. Moisture enters, the desiccant saturates, and fogging appears between the panes. It cannot be repaired; the unit is replaced.
- An over-wide cavity. Beyond a certain width convection starts inside the cavity and the benefit falls away.
- Ignoring climatic load. Pressure and temperature differences bow the panes; on large units this must be calculated.
What to write in a specification
State the pane build-up and thicknesses, the cavity width, the gas fill, the coating type and its surface number, the spacer type and the seal type. A specification that says "double glazing" is not buildable.
What we produce
We produce insulated glass units at our Riyadh factory to project dimensions, and either pane can be tempered or laminated according to the safety requirement of the position.